- Products
- Database Processing & High Density Storage
- Supermicro SYS-220BT-HNC9R BigTwin 2U Barebone 4-Node Dual Intel Xeon Scalable Processor Up to 6TB DRAM NVMe, SAS, SATA3 Network via AIOM
Supermicro SYS-220BT-HNC9R BigTwin 2U Barebone 4-Node Dual Intel Xeon Scalable Processor Up to 6TB DRAM NVMe, SAS, SATA3 Network via AIOM
• Mission Critical HPC
• Virtualized Big Data Analytics
• High-Density Storage RAID Array
Barebone BigTwin 2U Rackmount SuperServer 4-Node, Dual Intel Xeon Scalable, Intel C621A chipset, Up to 4TB in 20 DIMM Slots, SAS3 via Broadcom 3908, 6x 2.5in NVMe, SATA, SAS drive bays, network via AIOM, 2600W Redundant Power Supply (CSE-217BQ-000NP + X12DPT-B6)
1. Socket P+ (LGA 4189) support 3rd Gen Intel® Xeon® Scalable processors
2. Intel® C621A
3. 20 DIMM Slots (16 DIMM Slots + 4 Intel® Optane™ Persistent Memory Slots)
4. 1 PCIe 4.0 x16 (LP) slot; Tool-less support Internal PCIe 4.0 x8 for 2 M.2 NVMe/SATA support onboard Optional NVMe Boot Controller via AOC-SMG3-2M2-B
5. Network connectivity via AIOM (OCP 3.0 compliant)
6. 6 Hot-swap 2.5" drive bays; 6 PCIe 4.0 NVMe/SAS/SATA 2.5" drives
7. 4 cooling fans per 2U enclosure, 16.5K RPM; Shared Cooling Design Liquid Cooling Support
8. 2600W Redundant Power Supplies Titanium Level (96%+); Shared Power Design
9. Built-in SAS3 Support via Broadcom SAS3908
Extra Specifications for Supermicro SYS-220BT-HNC9R BigTwin 2U Barebone 4-Node Dual Intel Xeon Scalable Processor Up to 6TB DRAM NVMe, SAS, SATA3 Network via AIOM
Motherboard | ||
Motherboard | Super X12DPT-B6 | |
Processor (per Node) | ||
CPU | Dual Socket P+ (LGA 4189) | |
3rd Gen Intel® Xeon® Scalable processors | ||
Support CPU TDP 205W * | ||
Cores | 36C/72T | |
Note | *Certain CPUs with high TDP may be supported only under specific conditions. Please contact Supermicro Technical Support for additional information about specialized system optimization | |
System Memory (per Node) | ||
Memory | Intel® Optane™ persistent memory 200 series | |
Memory Capacity: 16 DIMM slots (16 DRAM + 4 PMem) | ||
Memory Type: 3200MHz ECC DDR4 RDIMM | ||
Up to 4TB: 16x 256 GB DRAM | ||
Up to 6TB: 8x 256 GB DRAM and 8x 512 GB PMem | ||
On-Board Devices (per Node) | ||
SAS | SAS3 (12Gbps) via Broadcom® 3908; RAID 0, 1, 5, 6, 10, 50 support | |
Chipset | Intel® C621A | |
Network Connectivity | Via AIOM | |
IPMI | Support for Intelligent Platform Management Interface v.2.0 | |
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support | ||
Input / Output (per Node) | ||
LAN | 1 RJ45 Dedicated BMC LAN port | |
USB | 2 USB 3.0 port(s) (2 rear) | |
Video | 1 VGA port(s) | |
Others | M.2 for boot drive only | |
System BIOS | ||
BIOS Type | AMI 32MB Flash ROM | |
Management | ||
Software | Watch Dog | |
KVM with dedicated LAN | ||
SuperDoctor® 5 | ||
Intel® Node Manager | ||
IPMI 2.0 | ||
SUM | ||
SSM | ||
SPM | ||
SuperCloud Composer | ||
Supermicro Out of Band (OOB) License (Included per Node) | ||
Power Configurations | ACPI / APM Power Management | |
PC Health Monitoring | ||
CPU | Monitors for CPU Cores, Chipset Voltages, Memory. | |
7+1 Phase-switching voltage regulator | ||
FAN | Status monitor for speed control | |
Pulse Width Modulated (PWM) fan connectors | ||
Fans with tachometer monitoring | ||
Temperature | Monitoring for CPU and chassis environment | |
Chassis | ||
Form Factor | 2U Rackmount | |
Model | CSE-217BQ-000NP | |
Dimensions and Weight | ||
Height | 3.47" (88mm) | |
Width | 17.68" (449mm) | |
Depth | 28.75" (730mm) | |
Package | 9.76" (H) x 24.65" (W) x 45.28" (D) | |
Weight | Net Weight: 54.5 lbs (24.7 kg) | |
Gross Weight: 85 lbs (38.6 kg) | ||
Available Color | Black | |
Front Panel | ||
Buttons | Power On/Off button | |
UID button | ||
LEDs | Network activity LEDs | |
Power status LED | ||
HDD activity LED | ||
Universal Information (UID) LED | ||
Drive Bays / Storage (per Node) | ||
Hot-swap | 6x 2.5" hot-swap NVMe/SATA/SAS drive bays (6x 2.5" NVMe hybrid) | |
System Cooling | ||
Fans | 4x 16.5K RPM Heavy Duty 8cm Fan(s) | |
Power Supply | ||
Total Output Power | 2600W : 208 - 240 Vac | |
2600W : 220 - 240 Vdc for CQC only | ||
Dimension (W x H x L) | 45 x 40 x 480 mm | |
AC Input | 208-240Vac / 12.5A-15A / 50-60Hz | |
220-240Vdc / 12.5A-13.5A (CQC only) | ||
+12V | Max: 216.6A / Min: 0A | |
12V SB | Max: 4.5A / Min: 0A | |
Certification | Titanium Level | |
Operating Environment | ||
RoHS | RoHS Compliant | |
Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) | |
Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) | ||
Operating Relative Humidity: 8% to 90% (Non-Condensing) | ||
Non-operating Relative Humidity: 5% to 95% (Non-Condensing) | ||
Product SKUs | ||
Product SKUs | SYS-220BT-HNC9R | |
Expansion Slots (per Node) | ||
PCI-Express (PCIe) | 1 PCIe 4.0 x16 LP slot(s) |
Name | Part Number | Qty. | Description | |
---|---|---|---|---|
Motherboard / Chassis | MBD-X12DPT-B6 | 4 | Super X12DPT-B6 Motherboard | |
Motherboard / Chassis | CSE-217BQ-000NP | 1 | 2U Chassis | |
Add-on Card / Module | AOC-S3908L-H8IR-16DD-P | 4 | 8 int 12Gb/s ports, x8 Gen4, ROC - LP, 16 HDDw/ exp,RoHS | |
Add-on Card / Module | AOC-SMG3-2H8M2-BW-P | 4 | 2x Hybrid M.2 riser carrier card for X12 BigTwin,RoHS | |
Backplane | BPN-NVME4-217BHQ-S6 | 1 | 2U 24-Slot 4-Node BigTwin Backplane Supports up to 6xNVMe4/SAS4/SATA3 per Node | |
Cable | CBL-PWCD-0376-IS | 2 | PWCD,US,IEC60320 C19 TO C20,940mm (3ft),14AWG,15A,250V,Black | |
Cable | CBL-SAST-1234F-100 | 4 | Slimline x8 (STR) to Slimline x8(STR),FFC,FOLD,33.5CM,10 | |
Drive Tray(s) | MCP-220-00144-0B-BULK | 24 | Black Gen3 hot-swap 2.5 inch HDD tray with lock, orange tab | |
Air Shroud | MCP-310-21730-0B | 4 | BigTwin 2U4N plastic air shroud for X12DPT-B | |
Riser Card | RSC-PR-6-X2 | 4 | 1U RHS TwinPro Riser card with one PCIe 4.0 x16 slot,HF,RoH | |
Storage Controller Card | SCC-F6N6T-B1 | 4 | 1U Storage Controller card for X12 2U4N BigTwin & FatTwin | |
Software | SFT-OOB-LIC | 4 | License key for enabling OOB BIOS management | |
Heatsink / Retention | SNK-P0077PW | 4 | 1U Passive CPU HS 92mm Width for X12 Whitley Platform | |
Heatsink / Retention | SNK-P0077VM | 4 | X12 ICX/CPX CPU Heatsink (78x113x25.5mm), VC Base w/ Channel | |
*Power Supply | PWS-2K60A-1R | 2 | 1U 2600W Redundant Titanium PWS, 45(W) X 40(H) X 480(L) | |
*Power Distributor | PDB-PT217-BGTWN | 1 | 2U Big Twin Power Distributor Board Support Redundant 2KW | |
*Fan | FAN-0183L4 | 4 | 80x80x38 mm, 16.5K RPM, Non-hot-swappable Middle Cooling Fan for X11 Twin Pro, X10 and X11 Big Twin Series Servers | |
*Rail Set | MCP-290-00172-0N | 1 | 2U non-tip rail set, quick release, default for 2,3U 17.6 | |
*Fan Holder | MCP-320-21702-0N | 2 | Bigtwin fan holder (with 4.1mm rubber feet)(hold 2 80x38 fans) |
Note:
• Parts with * are inside the chassis
• Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
Name | Part Number | Price | Add to Cart | Qty. | Description | |
---|---|---|---|---|---|---|
2.5" Tool-less NVMe Tray | MCP-220-00167-0B • | 0 | Black gen 8 hot-swap 2.5" Tool-less NVMe tray, orange tab (Qty as Needed) | |||
2.5" Tool-less SAS/SATA Tray | MCP-220-00147-0B • | 0 | Black gen 3 hot-swap 2.5" Tool-less HDD tray, red tab (Qty as Needed) | |||
CacheVault for RAID Controller | BTR-CVPM05 | 1 | Broadcom CacheVault | |||
CacheVault for RAID Controller | BKT-BBU-BRACKET-05 | 0 | Mounting Bracket (Qty per Node) | |||
HDD Dummy Tray | MCP-220-00185-0N | $ 21.50 | 0 | 2.5" HDD tray dummy cover for 2 slot (Qty as Needed) | ||
M.2 NVMe RAID Controller | AOC-SMG3-2M2-B-P | 0 | 2x M.2 NVMe RAID Controller Card, x8 Gen3 | |||
SPI Capable TPM Options | AOM-TPM-9670H-FIPS | 1 | SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor, Supporting FIPS 140-2 (Qty per Node) | |||
SPI Capable TPM Options | AOM-TPM-9671H-S | $ 52.00 | 1 | SPI Capable TPM 1.2 Provisioned for Server, Horizontal Form Factor (Qty per Node) | ||
SPI Capable TPM Options | AOM-TPM-9670H-S | $ 52.00 | 1 | SPI Capable TPM 2.0 Provisioned for Server, Horizontal Form Factor (Qty per Node) | ||
SuperCloud Composer License | SFT-SDDC-SINGLE | $ 281.00 | 0 | SDDC Monitor License - Single License per Monitored host | ||
System Management Suite | SFT-DCMS-Single | 0 | Supermicro System Management Software Suite node | |||
VROC Options | AOC-VROCPREMOD • | 1 | Intel VROC Premium, RAID 0, 1, 5, 10 (Qty per Node) | |||
VROC Options | AOC-VROCSTNMOD | 1 | Intel VROC Standard, RAID 0, 1, 10 (Qty per Node) |
Warranty: | 3 years labor, 1 year parts, 120 days advance replacement (doa) |
Coverage: | Replacement or repair |
Average Service Time: | Overnight replacement for 120 days, 2 weeks afterward |
E-mail: | returnservices@wiredzone.com |
If you need Technical Support for this item please contact: | |
Provider: | Supermicro |
Type of Support: | FULL |
Phone No.: | 408-503-8000 |
URL: | Click here for Manufacturer Website |