- Products
- Telco Data Center
- Supermicro AS-F1114S-RNTR A+ 4U Barebone Single AMD EPYC 7003/7002 Series Processor Up to 2TB SDRAM SATA3, NVMe Network via AIOM
Supermicro AS-F1114S-RNTR A+ 4U Barebone Single AMD EPYC 7003/7002 Series Processor Up to 2TB SDRAM SATA3, NVMe Network via AIOM
• Hyperscale / Hyperconverged
• HPC and Big Data
• Data Center Enterprise Applications
• Scale Out Storage
• Telco Data Center
• Virtualization Server
Barebone 4U Rackmount SuperServer Single AMD EPYC 7003/7002, System on Chip, Up to 2TB in 8 DIMM Slots, SATA3, NVMe, 6x 2.5in drive bays, network via AIOM, 2200W Redundant Power Supply (CSE-F418BC3-R2K20B + H12SSFR-AN6) - AS -F1114S-RNTR
1. Single AMD EPYC™ 7003/7002 Series Processor (The latest AMD EPYC™ 7003 Series Processor with AMD 3D V-Cache™ Technology requires BIOS version 2.3 or newer)
2. Up to 2TB ECC 3DS LRDIMM, up to DDR4-3200MHz; 8 DIMM slots
3. Expansion slots: 1 PCI-E 4.0 x16 (LP Riser), 1 PCI-E 4.0 x16 (for AIOM)
4. AIOM Network card, 1 dedicated IPMI LAN port
5. 1 VGA, 2 USB 3.0 ports
6. 6 Hot-swap 2.5" drive bays: 2 NVMe/SATA3, 4 SATA3 (optional NVMe with additional cables) M.2 Interface : 4 SATA/PCI-E 4.0 x4 M.2 Form Factor : 2242, 2260, 2280, 22110 M.2 Key : M-Key
7. 3x 4cm 17.6K RPM middle fans
8. 2200W Redundant Power Supplies Titanium Level (96%) (Full redundancy based on configuration and application load)
Extra Specifications for Supermicro AS-F1114S-RNTR A+ 4U Barebone Single AMD EPYC 7003/7002 Series Processor Up to 2TB SDRAM SATA3, NVMe Network via AIOM
Motherboard | ||
Motherboard | Super H12SSFR-AN6 | |
Processor/Chipset (per Node) | ||
CPU | Socket SP3 | |
Supports CPU TDP / cTDP up to 280W * | ||
Single AMD EPYC™ 7003/7002 Series Processor (The latest AMD EPYC™ 7003 Series Processor with AMD 3D V-Cache™ Technology requires BIOS version 2.3 or newer) | ||
Cores | Up to 64 Cores | |
Note | * Certain CPUs with high TDP may be supported only under specific conditions. Please contact Supermicro Technical Support for additional information about specialized system optimization | |
System Memory (per Node) | ||
Memory Capacity | 8 DIMM slots | |
8-channel memory bus | ||
Supports up to 2TB Registered ECC DDR4 3200MHz SDRAM in 8 DIMMs | ||
Memory Type | DDR4 3200 MHz Registered ECC, 288-pin gold-plated DIMMs | |
Memory Sizes | 8GB, 16GB, 32GB, 64GB, 128GB, 256GB | |
Memory Voltage | 1.2V | |
Error Detection | Corrects single-bit errors | |
Detects double-bit errors (using ECC memory) | ||
On-Board Devices | ||
Chipset | System on Chip | |
SATA | SATA3 (6Gbps) | |
Network Controllers | Flexible networking via AIOM (not included, must add 1 per node) | |
IPMI | Support for Intelligent Platform Management Interface v.2.0 | |
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support | ||
Graphics | ASPEED AST2600 BMC | |
Input / Output (per node) | ||
LAN | 1 RJ45 Dedicated IPMI LAN port | |
Flexible networking via AIOM | ||
USB | 2 USB 3.0 ports (rear) | |
VGA | 1 VGA port | |
Others | 1 COM port | |
1 TPM 2.0 header | ||
System BIOS | ||
BIOS Type | 256Mb SPI Flash EEPROM with AMI BIOS | |
Management | ||
Software | Watch Dog | |
KVM with dedicated LAN | ||
SuperDoctor® 5 | ||
IPMI 2.0 | ||
SSM , SUM | ||
Power Configurations | ACPI Power Management | |
PC Health Monitoring | ||
CPU | Monitors for CPU Cores | |
FAN | Status monitor for speed control | |
Pulse Width Modulated (PWM) fan connectors | ||
Fans with tachometer monitoring | ||
Temperature | Monitoring for CPU and chassis environment | |
Thermal Control for fan connectors | ||
Chassis | ||
Form Factor | 4U Rackmount | |
Model | CSE-F418BC3-R2K20B | |
Dimensions and Weight | ||
Width | 17.63" (448mm) | |
Height | 6.96" (177mm) | |
Depth | 29" (737mm) | |
Package | 28.3" (W) x 15.0" (H) x 42.4" (D) | |
Weight | Net Weight: 150 lbs (68.04 kg) | |
Gross Weight: 200 lbs (90.71 kg) | ||
Available Colors | Black | |
Front Panel (per node) | ||
Buttons | Power On/Off button | |
UID button | ||
LEDs | Power status LED | |
Hard drive activity LED | ||
Network activity LEDs | ||
Information LED (UID, Fan failure, Overheat) | ||
Expansion Slots (per node) | ||
PCI-Express | 1 PCI-E 4.0 x16 (Low-profile riser) | |
1 PCI-E 4.0 x8 (Internal RAID AOC) | ||
Drive Bays (per node) | ||
Hot-swap | 2 Hot-swap 2.5" NVMe/SATA3 and 4 SATA3 (optional NVMe with additional cables) | |
M.2 | M.2 Key: M-Key | |
M.2 Interface: 4 SATA/PCI-E 4.0 x4 | ||
M.2 Form Factor: 2242, 2260, 2280, 22110 | ||
Backplane | ||
Backplane | 1 SATA/NVMe backplane | |
System Cooling (per node) | ||
Fans | 3x 4cm 17.6K RPM middle fans | |
Power Supply | ||
Power Supply | 2200W Redundant Power Supplies with PMBus | |
Total Output Power and Input | 1200W with Input 100-127Vac | |
1800W with Input 200-220Vac | ||
1980W with Input 220-230Vac | ||
2090W with Input 230-240Vac | ||
2200W with Input 220-240Vac (for UL/cUL use only) | ||
2090W with Input 230-240Vdc (for CCC only) | ||
AC Input Frequency | 50-60Hz | |
Dimension (W x H x L) | 76 x 40 x 336 mm | |
+12V | Max: 150A / Min: 0A (200-220Vac) | |
Max: 165A / Min: 0A (220-230Vac) | ||
Max: 100A / Min: 0A (100-127Vac) | ||
Max: 174.17A / Min: 0A (230-240Vac) | ||
Max: 183.3A / Min: 0A (220-240Vac) | ||
5VSB | Max: 1A / Min: 0A | |
Output Type | Backplanes (gold finger) | |
Certification | Titanium Level | |
Operating Environment | ||
RoHS | RoHS Compliant | |
Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) | |
Operating Relative Humidity: 8% to 90% (non-condensing) | ||
Non-operating Relative Humidity: 5% to 95% (non-condensing) | ||
Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) | ||
Product SKUs | ||
Product SKUs | A+ Server F1114S-RNTR (Black) |
Name | Part Number | Qty. | Description | |
---|---|---|---|---|
Motherboard / Chassis | MBD-H12SSFR-AN6 | 8 | Super H12SSFR-AN6 Motherboard | |
Motherboard / Chassis | CSE-F418BC3-R2K20B | 1 | 4U Chassis | |
Backplane | BPN-ADP-X11DPFR | 8 | Power distribution board | |
Backplane | BPN-NVME4-F418-B6S6 | 8 | 1U 6-Slot SFF Backplane Supports 6xSAS3/SATA3/NVMe4 Storage Devices,HF,RoHS | |
Cable 1 | CBL-0486L | 16 | 2x2 to 2x2 15cm Power Cable HF | |
Cable 2 | CBL-OTHR-1211-28 | 8 | 2x10pin (PH 1) to 2x10pin (PH 1),11CM,28AWG,1A/pin,RoHS | |
Cable 3 | CBL-PWCD-0900 | 4 | PWCD,US/EU/Canada/China/Australia,IEC60320 C14 TO C13,4FT,17 | |
Cable 4 | CBL-SAST-1223-85 | 8 | Slimline x8 (LE) to 2x Slimline x4 (STR),22/22CM,85 OHM | |
Cable 5 | CBL-SAST-1247-100 | 16 | Slimline x4 (LE) to MiniSAS HD x4 (STR),47CM,100 OHm,Ro | |
Heatsink / Retention | SNK-P0062P | 8 | 1U Passive CPU Heat Sink for AMD Socket SP3 Processors | |
Riser Card | RSC-S-6G4 | 8 | 1U LHS Standard riser card with one PCI-E 4.0 x16 slot,HF,Ro | |
Power Supply | PWS-2K20A-1R | 4 | 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm | |
Backplane | BPN-PDB-X12DPFR | 2 | FatTwin 4U 4-Node PDB with LCMC for RIO Platform | |
Rail Set | MCP-290-41803-0N | 1 | Fat twin F418 / F424 Static Rail set support 28-33.5 inch depth rail,RoHS/REACH,PBF | |
Software | SFT-OOB-LIC • | 1 | OOB Management Package (per node license) |
Name | Part Number | Price | Add to Cart | Qty. | Description | |
---|---|---|---|---|---|---|
Cable(s) for Additional NVMe Support | CBL-SAST-1223-85 | $ 33.50 | 2 | Slimline x8 (LE) to 2x Slimline x4 (STR),22/22CM,85 OHM | ||
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
Warranty: | 3 years labor, 1 year parts, 1 year advance replacement (doa) |
Coverage: | Replacement or repair |
Average Service Time: | Overnight replacement for 1 year, 2 weeks afterward |
E-mail: | returnservices@wiredzone.com |
If you need Technical Support for this item please contact: | |
Provider: | Supermicro |
Type of Support: | FULL |
Phone No.: | 408-503-8000 |
URL: | Click here for Manufacturer Website |