- Products
- 5G Core & Edge
- Supermicro SSG-640P-E1CR36L Storage DP 4U Barebone Dual 3rd Gen Intel Xeon Scalable processors Up to 4TB RDIMM/LRDIMM/Intel DCPMM SATA3, SAS3, NVMe hybrid, M.2 NVMe Dual 10GbE, IPMI LAN port
Supermicro SSG-640P-E1CR36L Storage DP 4U Barebone Dual 3rd Gen Intel Xeon Scalable processors Up to 4TB RDIMM/LRDIMM/Intel DCPMM SATA3, SAS3, NVMe hybrid, M.2 NVMe Dual 10GbE, IPMI LAN port
• Enterprise Server
• iSCSI SAN
• HPC, Data Center
• Database Processing & Storage
• Corporate Database
• Density Optimized Storage Building Block
Barebone 4U Rackmount SuperServer 3rd Gen Intel Xeon Scalable processors, Intel C621A chipset, Up to 4TB in 16 DIMM slots, LRDIMM/RDIMM, + 2 Intel Optane Persistent Memory Dedicated Slots, SATA3/SAS3 via HBA Controller support via Broadcom 3808, 36x 3.5in SATA3/SAS3 drive bays (4x 3.5in NVMe hybrid), 1x M.2 NVMe, 2x 10GbE BaseT LAN Ports, IPMI LAN port, 2 SuperDOM (Disk on Module) port, 1600W Redundant Power Supply (CSE-847BTS-R1K68LPBP4 + X12DPi-NT6)
1. Dual socket 3rd Gen Intel® Xeon® Scalable processors, up to 72 Cores Per Node
2. 16 ECC DDR4-3200: LRDIMM/RDIMM + 2 Intel® Optane™ Persistent Memory Dedicated Slots
3. 2x 10Gbe Server remote management: IPMI 2.0 / KVM over LAN / Media over LAN per node
4. 36 3.5"/2.5" Hot-swap SAS3/SATA3 drives (4 Hybrid NVMe), 2x Rear SATA Slots, 1x SATA/NVMe M.2 (form factor: 2280 and 22110)
5. 7x 8cm hot-swap counter-rotate redundant PWM cooling fans
6. 1600W Redundant Power Supplies Titanium Level (96%)
7. HBA Controller support via Broadcom® 3808
Extra Specifications for Supermicro SSG-640P-E1CR36L Storage DP 4U Barebone Dual 3rd Gen Intel Xeon Scalable processors Up to 4TB RDIMM/LRDIMM/Intel DCPMM SATA3, SAS3, NVMe hybrid, M.2 NVMe Dual 10GbE, IPMI LAN port
| Motherboard | ||
| Motherboard | Super X12DPi-NT6 | |
| Processor | ||
| CPU | 3rd Gen Intel® Xeon® Scalable processors | |
| Dual Socket P+ (LGA-4189) | ||
| Support CPU TDP 120-270W | ||
| Cores | Up to 38C/76T; Up to 57MB Cache | |
| System Memory | ||
| Memory | Memory Capacity: 16 DIMM slots | |
| Memory Type: 3200MHz ECC DDR4 RDIMM;LRDIMM;DCPMM | ||
| Up to 4TB: 16x 256 GB DRAM | ||
| Memory Voltage | 1.2 V | |
| Error Detection | ECC | |
| On-Board Devices | ||
| Chipset | Intel® C621A | |
| Network Connectivity | 2x 10GbE BaseT with Intel® X550 | |
| IPMI | Support for Intelligent Platform Management Interface v.2.0 | |
| IPMI 2.0 with virtual media over LAN and KVM-over-LAN support | ||
| Input / Output | ||
| LAN | 1 RJ45 Dedicated IPMI LAN port | |
| USB | 4 USB 3.0 port(s) (4 Rear_USB) | |
| Video | 1 VGA port(s) | |
| Serial Port | 1 COM Port(s) (1 rear) | |
| DOM | 2 Super DOM (Disk on Module) port | |
| System BIOS | ||
| BIOS Type | AMI 128MB SPI Flash EEPROM | |
| Management | ||
| Software | Watch Dog | |
| NMI | ||
| SuperDoctor® 5 | ||
| IPMI 2.0 | ||
| SUM | ||
| Power Configurations | Power-on mode for AC power recovery | |
| ACPI Power Management | ||
| PC Health Monitoring | ||
| CPU | Monitors for CPU Cores, Chipset Voltages, Memory | |
| 4+1 Phase-switching voltage regulator | ||
| FAN | Status monitor for speed control | |
| Pulse Width Modulated (PWM) fan connectors | ||
| Fans with tachometer monitoring | ||
| Temperature | Monitoring for CPU and chassis environment | |
| Thermal Control for fan connectors | ||
| Chassis | ||
| Form Factor | 4U Rackmount | |
| Model | CSE-847BTS-R1K68LPBP4 | |
| Dimensions and Weight | ||
| Height | 7" | |
| Width | 17.2" | |
| Depth | 27.5" | |
| Package | 15" (H) x 27" (W) x 39" (D) | |
| Weight | Net Weight: 65.5 lbs (29.7 kg) | |
| Gross Weight: 102.5 lbs (46.4 kg) | ||
| Available Color | Silver | |
| Front Panel | ||
| Buttons | Power On/Off | |
| LEDs | HDD activity | |
| Power status | ||
| Network activity | ||
| System information (overheat/UID) | ||
| Expansion Slots | ||
| Note | PCIe slot 1/2 is occupied by the JBOD Expansion/Storage Controller | |
| PCI-Express (PCIe) | 3 PCIe 4.0 x16 LP slot(s) | |
| 1 PCIe 4.0 x8 LP slot(s) | ||
| Drive Bays / Storage | ||
| Hot-swap | 36x 3.5" hot-swap SATA3/SAS3 drive bays (4x 3.5" NVMe hybrid) | |
| M.2 | 1 M.2 NVMe | |
| System Cooling | ||
| Fans | 7 Heavy Duty 8cm Fan(s) | |
| Power Supply | ||
| Dimension (W x H x L) | 76.5 x 40 x 360 mm | |
| AC Input | 100-140Vac / 7A-10A / 50-60Hz | |
| 180-240Vac / 8A-11A / 50-60Hz | ||
| +12V | Max: 66A / Min: 0A (100Vac-127Vac) | |
| Max: 133A / Min: 0A (200Vac-240Vac) | ||
| 5V SB | Max: 1A / Min: 0A | |
| Output Type | 27 Pairs Gold Finger Connector | |
| Certification | Titanium Level | |
| Operating Environment | ||
| RoHS | RoHS Compliant | |
| Environmental Spec. | Operating Temperature: 10°C ~ 35°C (50°F ~ 95°F) | |
| Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) | ||
| Operating Relative Humidity: 8% to 90% (Non-Condensing) | ||
| Non-operating Relative Humidity: 5% to 95% (Non-Condensing) | ||
| Product SKUs | ||
| Product SKUs | SSG-640P-E1CR36L | |
| Name | Part Number | Qty. | Description | |
|---|---|---|---|---|
| Motherboard / Chassis | MBD-X12DPi-NT6 | 1 | Super X12DPi-NT6 Motherboard | |
| Motherboard / Chassis | CSE-847BTS-R1K68LPBP4 | 1 | 4U Chassis | |
| Add-on Card / Module | AOC-S3808L-L8IT-P | 1 | 8 int 12Gb/s SAS3 ports, x8 Gen4, HBA - LP,122HDDw/exp,R | |
| Add-on Card / Module | AOM-SAS3-8I8E-LP | 1 | 8-port Mini SAS HD Int-to-Ext Cable Adapter W/LP Bracket | |
| Backplane | BPN-SAS3-826EL1-N4 | 1 | 12-Port 2U BPN with EXP up to 8x3.5" SAS3 HDD& 4xNVMe | |
| Backplane | BPN-SAS3-846EL1-N8 | 1 | 24-Port 4U Exp. BPN Support up-to 16x3.5"HDD and 8XNVMe | |
| Cable | CBL-0296L | 1 | 9" 4 PIN FAN PWS EXTENSION CORD, PBF | |
| Cable | CBL-CDAT-0728 | 1 | 4 Pin to 4 Pin I2C Cable, 65cm, 26AWG, 4 Wires, Pinout 1-1 | |
| Cable | CBL-SAST-0531 | 4 | Internal Mini-SAS HD to Mini-SAS HD 80cm,30AWG,12Gb/s | |
| Cable | CBL-SAST-1264-100 | 1 | Slimline x8 (STR) to 2x MiniSAS HD x4,65CM,100 OHM,RoHS | |
| Cable | CBL-0071L | 1 | ROUND 16 TO 16 PIN RIBBON FP CABLE 30"L, LF | |
| Cable | CBL-0160L | 2 | US POWER CORD 16AWG, PB FREE | |
| Cable | CBL-PWEX-1079 | 7 | PWEX,FAN,1X4/P2.5 TO 1X4/P2.54,37CM,22AWG,5A/pin,RoHS | |
| Parts | MCP-260-00042-0N | 1 | STD I/O shield for X9 socket R server MB with Gasket. | |
| Software | SFT-OOB-LIC | 1 | License key for enabling OOB BIOS management | |
| Heatsink / Retention | SNK-P0078P | 1 | 2U Passive CPU Heat Sink for X12 Generation Intel Whitley and Cedar Island Platforms | |
| Heatsink / Retention | SNK-P0078PC | 1 | 2U Passive CPU Heat Sink w/ a Side Air Channel for X12 Generation Intel Whitley and Cedar Island Platforms | |
| *Power Supply | PWS-1K68A-1R | 2 | 1U 1600W Redundant Titanium Power Supply 76mm width 27Pair,PBF | |
| *Power Distributor | PDB-PT847-8824 | 1 | 24pin standard output with 5V high current 100Amp power distributor board for SC847 | |
| *Fan | FAN-0166L4 | 7 | 80x80x38 mm, 13.5K RPM, Optional Middle Cooling Fan for 2U Ultra Series Servers (Hot-swappable Version of FAN-0162L4) | |
| *Front Panel | FPB-TB826-T | 1 | Chassis transfer board for SC826 | |
| *Drive Tray(s) | MCP-220-00075-0B | 36 | Black gen 5.5 hot-swap 3.5" HDD tray | |
| *Drive Tray(s) | MCP-220-84708-ASM | 1 | SC847B LP MB Tray assembly,HF,RoHS/REACH | |
| *Rail Set | MCP-290-00057-0N | 1 set | Rail set, quick/quick, default for 4U 17.2" W | |
| *Rail Set | MCP-410-00007-0N | 1 | Rail screw bag | |
| *Air Shroud | MCP-310-49004-0N | 1 | SC847/417 DP X9 universal PC air shroud 1368x13/12x13MB |
Note:
• Parts with * are inside the chassis
• Excessive parts might not be shipped, including but not limited to excessive drive trays, fans, riser brackets, air shrouds, IO shields, cables.....etc.
| Name | Part Number | Price | Add to Cart | Qty. | Description | |
|---|---|---|---|---|---|---|
| Bezel | MCP-210-84601-0B • | 0 | Black Front Bezel For SC846 Chassis | |||
| Converter Tray | MCP-220-00043-0N • | 0 | Black hot-swap gen 4 3.5 to 2.5 HDD tray | |||
| External SAS Cable (FOR JBOD) | CBL-SAST-0573 • | 0 | 1m External Mini SAS HD to External Mini SAS HD.28AWG | |||
| IPASS Cable | CBL-SAST-0388L-02 • | 0 | 30AWG Ipass to 4SATA 90/90/70/70CM W/ 90CM SB | |||
| Network Cards | AOC-S40G-I2Q | $ 377.00 | 0 | Standard LP 2-port 40GbE controller, Intel Fortville XL710 | ||
| Network Cards | More | 0 | AOC Compatibility Matrix (Select Storage & Generation) | |||
| Network Cards | AOC-SGP-I2 • | 0 | Standard LP 2-port GbE, Intel 82575 | |||
| Network Cards | AOC-S25G-M2S | $ 204.00 | 0 | Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN | ||
| Power Cord | CBL-PWCD-0579-1 | $ 23.00 | 0 | Power Cord Type IEC (C14 to C13) 6 ft (14AWG), 15A, 250V | ||
| Power Cord | CBL-PWCD-0300-IS | $ 20.00 | 0 | PWCD,US,IEC60320 C14 TO C13,6FT,18AWG,RoHS/REACH | ||
| Power Cord | CBL-PWCD-0579 | $ 23.00 | 0 | Power Cord Type IEC (C14 to C13) 6 ft (14AWG), 15A, 250V | ||
| Rear 3808 SAS Support | AOC-S3808L-L8IT-O • | 1 | 3808 SAS Controller | |||
| Rear 3808 SAS Support | CBL-SAST-1270-100 | 1 | SlimSASx8 STR SFF-8654 to 8xSATA 7-pin,70CM,100 Ohm,RoHS | |||
| Rear 3908 SAS Support | AOC-S3908L-H8IR-16DD-O • | 1 | 3908 SAS Controller | |||
| Rear 3908 SAS Support | CBL-SAST-1270-100 | 1 | SlimSASx8 STR SFF-8654 to 8xSATA 7-pin,70CM,100 Ohm,RoHS | |||
| Toolless Converter Tray | MCP-220-00118-0B • | 0 | Black gen-5.5 tool-less 3.5-to-2.5 converter drive tray,RoHS/REACH | |||
| TPM | AOM-TPM-9670V-O • | 1 | TPM 2.0, vertical form factor, provisioned for server | |||
| TPM | AOM-TPM-9671V-O | 1 | TPM 1.2, vertical form factor, provisioned for server |
| Warranty: | 3 years labor, 1 year parts, 1 year advance replacement (doa) |
| Coverage: | Replacement or repair |
| Average Service Time: | Overnight replacement for 1 year, 2 weeks afterward |
| E-mail: | returnservices@wiredzone.com |
| If you need Technical Support for this item please contact: | |
| Provider: | Supermicro |
| Type of Support: | FULL |
| Phone No.: | 408-503-8000 |
| URL: | Click here for Manufacturer Website |