Server Barebone 1U for Dual Intel Xeon processor E5-2600 v4/v3 families, Supports up to 3TB DDR4 ECC LRDIMM, up to 2400MHz (24x 288-pin sockets) - On-Board : SATA3 6Gbps (RAID), IPMI 2.0, 2x 10GBase-T LAN, VGA - Includes : 10x 2.5in Hot-swap drive bays, 6x NVMe ports (NVMe from CPU 1), 4x NVMe/SAS3 Hybrid ports (NVMe from CPU2), 2x Riser Cards, 2x Heatsinks, 1000W Redundant 80 Plus Titanium Power Supply,MBD-X10DRU-i+ Motherboard, SC119UAC2-R750 1U Chassis (Black)
1. Dual socket R3 (LGA 2011) supports Intel® Xeon® processor E5-2600 v4 † /v3 family; QPI up to 9.6GT/s
2. Up to 3TB † ECC 3DS LRDIMM, up to DDR4- 2400 † MHz; 24x DIMM slots
3. 3 PCI-E 3.0 x8 slots (2 FH 10.5" L, 1 LP)
4. 2x 10GBase-T ports
5. 10 2.5" Hot-swap Drive Bays: 6 NVMe ports (NVMe from CPU 1); 4 NVMe/SAS3 hybrid ports for optional SAS3/SATA3** (NVMe from CPU 2)
6. 8 heavy duty fans w/ optimal fan speed control
7. 1000W Redundant Power Supplies Titanium Level (96%)
Extra Specifications for Supermicro SYS-1028U-TN10RT+ 1U Barebone Dual Intel Processor
Product SKUs | ||
Product SKUs | SuperServer 1028U-TN10RT+ (Black) | |
Motherboard | ||
Motherboard | Super X10DRU-i+ | |
Processor/Cache | ||
CPU | Dual Socket R3 (LGA 2011) | |
Intel® Xeon® processor E5-2600 v4 † / v3 family (up to 160W TDP) * | ||
Cores / Cache | Up to 22 Cores † / Up to 55MB † Cache | |
System Bus | QPI up to 9.6 GT/s | |
Note | † BIOS version 2.0 or above is required | |
* Please contact Supermicro Technical Support for additional information about frequency optimized CPUs and specialized system optimization. | ||
System Memory | ||
Memory Capacity | 24x 288-pin DDR4 DIMM slots | |
Up to 3TB † ECC 3DS LRDIMM, 768GB ECC RDIMM | ||
Memory Type | 2400 † /2133/1866/1600MHz ECC DDR4 SDRAM 72-bit | |
2666/2400 ECC DDR4 NVDIMM | ||
DIMM Sizes | 64GB, 32GB, 16GB, 8GB, 4GB | |
NVDIMM: 16GB | ||
Memory Voltage | 1.2 V | |
Error Detection | Corrects single-bit errors | |
On-Board Devices | ||
Chipset | Intel® C612 chipset | |
SATA | SATA3 (6Gbps) with RAID 0, 1, 5, 10 | |
IPMI | Support for Intelligent Platform Management Interface v.2.0 | |
IPMI 2.0 with virtual media over LAN and KVM-over-LAN support | ||
ASPEED AST2400 BMC | ||
Network Connectivity | 2 10GBase-T ports via AOC-URN6-i2XT | |
Intel® X540 10GBase-T | ||
1 Realtek RTL8211E PHY (dedicated IPMI) | ||
Graphics | ASPEED AST2400 BMC | |
Input / Output | ||
NVMe/SAS | 6 NVMe ports (NVMe from CPU 1) | |
4 NVMe/SAS3** Hybrid ports (NVMe from CPU 2) | ||
LAN | 2 RJ45 10GBase-T ports | |
1 RJ45 Dedicated IPMI LAN port | ||
USB | 5 USB 3.0 ports (2 rear, 2 front, 1 Type A) | |
Video | 1 VGA Connector | |
Serial Port | 1 Serial header | |
DOM | 2 Super DOM (Disk on Module) ports | |
System BIOS | ||
BIOS Type | 128Mb SPI Flash EEPROM with AMI BIOS | |
BIOS Features | SMBIOS 2.7.1 | |
USB Keyboard support | ||
Plug and Play (PnP) | ||
UEFI 2.3.1 | ||
PCI 2.3 | ||
ACPI 1.0 / 2.0 / 3.0 / 4.0 | ||
APM 1.2 | ||
Management | ||
Software | Watch Dog | |
NMI | ||
SuperDoctor® 5 | ||
Intel® Node Manager 3.0 | ||
SUM and SSM | ||
Optional IPMI 1.5 / 2.0 | ||
Power Configurations | Power-on mode for AC power recovery | |
ACPI Power Management | ||
Chassis | ||
Form Factor | 1U Rackmount | |
Model | CSE-119UAC2-R1K02 | |
Dimensions and Weight | ||
Height | 1.7" (43mm) | |
Width | 17.2" (437mm) | |
Depth | 28.5" (724mm) | |
Gross Weight | 48 lbs (21.8 kg) | |
Available Color | Black | |
Front Panel | ||
Buttons | Power On/Off button | |
System UID button | ||
LEDs | Power LED | |
Hard drive activity LED | ||
UID LED | ||
2x Network activity LEDs | ||
Expansion Slots | ||
PCI-Express | 3 PCI-E 3.0 x8 slots (2 Full-height 10.5" L; 1 Low-profile) | |
Drive Bays | ||
Hot-swap | 10x 2.5" Hot-swap drive bays | |
6 NVMe ports (NVMe from CPU 1) | ||
4 NVMe/SAS3 hybrid ports for optional SAS3/SATA3** (NVMe from CPU 2) ** Note: SAS3/SATA3 support requires additional parts in optional parts list | ||
System Cooling | ||
Fans | 8 heavy duty fans with optimal fan speed control | |
Air Shroud | 1 Air Shroud | |
Power Supply | ||
Power Supply | 1000W Redundant Power Supplies with PMBus | |
Total Output Power | 800W: 100 – 127Vac | |
1000W: 200 – 240Vac | ||
1000W: 200 – 240Vdc (for CCC only) | ||
Dimension (W x H x L) | 73.5 x 40 x 203 mm | |
Input | 100-127Vac / 9.8 - 7A / 50-60Hz | |
200-240Vac / 7 - 5A / 50-60Hz | ||
200-240Vdc / 7 - 5A (for CCC only) | ||
+12V | Max: 66.7A / Min: 0A (100-127Vac) | |
Max: 83A / Min: 0A (200-240Vac) | ||
Max: 83A / Min: 0A (200-240Vdc) | ||
12Vsb | Max: 2.1A / Min: 0A | |
Output Type | 25 Pairs Gold Finger Connector | |
Certification | Titanium Level | |
PC Health Monitoring | ||
Voltage | Monitors for CPU Cores, +1.8V, +3.3V, +5V, +12V, +3.3V Standby, +5V Standby, VBAT, Memory Voltages. | |
5+1 Phase-switching voltage regulator | ||
FAN | Status monitor for speed control | |
Pulse Width Modulated (PWM) fan connectors | ||
8x 4-pin fan headers | ||
Temperature | Monitoring for CPU and chassis environment | |
CPU thermal trip support | ||
Thermal Monitor 2 (TM2) support | ||
PECI | ||
Thermal Control for 8x Fan Connectors | ||
Support to monitor Supermicro AOC temperatures from IPMI or SD 5 | ||
LED | UID/Remote UID | |
CPU / System Overheat LED | ||
Suspend static indicator LED | ||
Memory DIMM ECC error LEDs | ||
Other Features | Chassis intrusion detection | |
Chassis intrusion header | ||
SDDC Support | ||
RoHS | ||
4x 8-pin GPU power connectors | ||
Operating Environment / Compliance | ||
RoHS | RoHS Compliant | |
Environmental Spec. | Operating Temperature: 10°C to 35°C (50°F to 95°F) | |
Non-operating Temperature: -40°C to 70°C (-40°F to 158°F) | ||
Operating Relative Humidity: 8% to 90% (non-condensing) | ||
Non-operating Relative Humidity: 5% to 95% (non-condensing) |
Name | Part Number | Qty. | Description | |
---|---|---|---|---|
Motherboard / Chassis | MBD-X10DRU-i+ | 1 | Super X10DRU-i+ Motherboard | |
Motherboard / Chassis | CSE-119UAC2-R750 | 1 | CSE-119UAC2-R750 Chassis | |
Air Shroud | MCP-310-81903-0B | 1 | Mylar air shroud set for SC819U,119U (X10DRU+),HF | |
Add-on Card / Module | AOC-URN6-I2XT-P | 1 | AOC-URN6-I2XT | |
Backplane | BPN-SAS3-116A-N10 | 1 | 10-port 1U SAS3 12Gbps Hybrid backplane, support up to 10x 2.5-inch NVMe storage devices, 4 of them are SAS3/SATA3 drives compatible. | |
Cable 1 | CBL-PWEX-0780 | 1 | PWYCB,2X4F/GPU-White to TWO 2X2F,P4.2, (5,12V),40/40CM,18AWG,RoHS | |
Cable 2 | CBL-PWEX-0781 | 1 | PWYCB,2X4F/GPU-White to TWO 2X2F,P4.2, (5,12V),65/65CM,18AWG,RoHS | |
Cable 3 | CBL-SAST-0818 | 5 | OCuLink v. 1.0,INT,PCIe NVMe SSD, 55CM,34AWG | |
Cable 4 | CBL-SAST-0819 | 3 | OCuLink v 1.0,INT,PCIe NVMe SSD, 65CM,34AWG,RoHS/REACH | |
Cable 5 | CBL-SAST-0820 | 2 | OCuLink v. 1.0,INT,PCIe NVMe SSD, 85CM,34AWG,RoHS/REACH | |
Parts | MCP-130-81901-0N | 1 | Oculink cable connection plastic holder for AOC-URN6-i2XT | |
Parts | MCP-150-00009-0B | 1 | Internal AOC rubber support for SC819U, 119U | |
Manual | MNL-1812-QRG | 1 | QRG for SYS-1028U-TN10RT+ | |
Riser Card | RSC-R1UW-E8R | 1 | 1U RHS WIO Riser card with one PCI-E x8 slot | |
Riser Card | RSC-UN4-88 | 1 | RSC-UN4-88 | |
Heatsink / Retention | SNK-P0057PSU | 2 | 1U Passive CPU Heat Sink for X10 1U 24-DIMM Ultra and Super Blade Series Servers,RoHS/REACH | |
Power Supply | PWS-1K02A-1R | 2 | 1U 1000W Redundant Power Supply 73.5mm width Titanium Level,RoHS/REACH |
Name | Part Number | Price | Add to Cart | Qty. | Description | |
---|---|---|---|---|---|---|
Cable | CBL-SAST-0880 | $ 18.50 | 0 | MINI SAS(RA-RS EXIT)-4 SATA,INT,55/55/55/55CM,55CM SB,30AWG for optional 4x SATA3 | ||
Storage Control Card and Cable(s) | AOC-S3008L-L8e | $ 234.50 | 0 | Std LP, 8 internal ports, 12Gb/s per port- Gen3, 122HDD, HBA | ||
Storage Control Card and Cable(s) | AOC-S3008L-L8i | $ 234.50 | 0 | Std LP, 8 internal ports, 12Gb/s per port- Gen3, 63HDD, RAID 0,1,1E | ||
Storage Control Card and Cable(s) | AOC-S3108L-H8iR | $ 603.00 | 0 | Std LP, 8 internal ports, 12Gb/s per port- Gen3, 240HDD, RAID 0, 1, 5, 6, 10, 50, 60 | ||
Network Card(s) | AOC-SGP-i2/4 | 0 | Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350 | |||
Network Card(s) | AOC-STGN-i1S/i2S | 0 | Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN | |||
Network Card(s) | AOC-STG-b4S | 0 | Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S | |||
Network Card(s) | AOC-STG-i2T | $ 312.50 | 0 | Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540 | ||
Network Card(s) | AOC-STG-i2 | 0 | Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB | |||
Network Card(s) | AOC-S40G-i2Q | $ 385.00 | 0 | Standard LP 2-port 40GbE controller, based on Intel Fortville XL710 | ||
Network Card(s) | More | 0 | AOC Compatibility Matrix | |||
CacheVault(s) | BTR-CV3108-1U1 | $ 322.00 | 0 | CacheVault for Broadcom 3108 with Supercap mounting in 1U 40x56 fan tray | ||
CacheVault(s) | BTR-TFM8G-LSICVM02 & BKT-BBU-BRACKET-05 | 0 | CacheVault for Broadcom 3108; Supercap mounting bracket for PCI-E location | |||
Drive Tray(s) | MCP-220-00047-0B | $ 18.50 | 0 | Black gen 3rd hot-swap 2.5" HDD tray | ||
1U Cable Management Arm | MCP-290-00152-0N | $ 147.00 | 1 | 1U Supermicro Cable Management Arm 2nd Gen | ||
Global Services & Support | OS4HR3/2/1 | 0 | 3/2/1-year onsite 24x7x4 service | |||
Global Services & Support | OSNBD3/2/1 | 0 | 3/2/1-year onsite NBD service | |||
Software | SFT-OOB-LIC • | 1 | OOB Management Package (per node license) | |||
Software | SFT-DCMS-Single | 1 | DataCenter Management Package (per node license) |
Warranty: | 3 years labor, 1 year parts, 1 year advance replacement (doa) |
Coverage: | Replacement or repair |
Average Service Time: | Overnight replacement for 1 year, 2 weeks afterward |
E-mail: | returnservices@wiredzone.com |
If you need Technical Support for this item please contact: | |
Provider: | Supermicro |
Type of Support: | FULL |
Phone No.: | 408-503-8000 |
URL: | Click here for Manufacturer Website |