Main Specifications |
Device Type | GPU SuperServer |
Built-in Devices | Super X13DEG-D |
Form Factor | 10U Rackmount - CSE-GP1001TS-R000NPF |
Dimensions (WxDxH) | Height 17.2" (438.8 mm) x Width 17.6" (449 mm) x Depth 33.2" (843.28 mm) |
Weight | Gross Weight: 341 lbs (155 kg) - Net Weight: 293 lbs (133 kg) |
Enclosure Color | Silver |
GPU Support | NVIDIA HGX B200 8-GPU (Included) |
Processor |
Processor Installed | Two Intel Xeon Scalable 8570 5th Generation Processor (Installed) With 56-Core/112 Thread (2.10GHz) |
System Memory |
Memory Installed | 3TB DDR5-4800MHz |
Drive Bays |
Hard Drive Installed | 8x 3.8TB U.3 NVMe Solid-state Drive (SSD), 2x 1.92TB M.2 NVMe Solid-state Drive (SSD) |
On-Board Devices |
Network Connectivity | 8x Single 400G NDR/ETH OSFP And 1x NVIDIA BlueField-3 DPU 200Gb/s (Included) |
Chipset | System on Chip |
TPM | 1 TPM Header |
Input / Output |
USB(s) | 2 USB 3.0 Type-A ports(Front) |
Video Output | 1 VGA port |
System BIOS |
BIOS Type | AMI 32MB UEFI |
Management |
Software | SuperCloud Composer, Supermicro Server Manager (SSM), Supermicro Update Manager (SUM), Supermicro SuperDoctor® 5 (SD5), Super Diagnostics Offline (SDO), Supermicro Thin-Agent Service (TAS), SuperServer Automation Assistant (SAA) New! |
Power Configurations | Power-on mode for AC power recovery, ACPI Power Management |
Security |
Hardware | Trusted Platform Module (TPM) 2.0 |
PC Health Monitoring |
CPU | Monitors for CPU Cores, Chipset Voltages, Memory, 8+4 Phase-switching voltage regulator |
FAN | Fans with tachometer monitoring, Status monitor for speed control, Pulse Width Modulated (PWM) fan connectors |
Temperature | Monitoring for CPU and chassis environment, Thermal Control for fan connectors |
Front Panel |
LEDs | HDD activity, Network activity LEDs, System information (overheat/UID), UID |
Buttons | Power On/Off, UID/ Reset button |
Expansion / Connectivity |
Expansion Slots Total (Free) | Default: 8 PCIe 5.0 x16 LP slots, 2 PCIe 5.0 x16 FHHL slots |
M.2 | 2 M.2 PCIe 3.0 x4 NVMe slots (M-key 2280/22110; VROC required for RAID) |
Drive Bays / Storage |
Drive Bays Configuration | Default: 10 front hot-swap 2.5" PCIe 5.0 x4 NVMe drive bays (NVMe support may require additional storage controller and/or cables) |
System Cooling |
Fans/Air Shroud | 15 heavy duty hot-swappable 80mm Fan(s) |
| 4 heavy duty internal 60mm Fan(s) |
Power Supply |
Power Supply | 6x 5250W Titanium Level Power Supplies |
Environmental |
Operating Environment | Operating Relative Humidity: 8% to 90% (non-condensing) |
| Non-operating Relative Humidity: 5% to 95% (non-condensing) |
| Non-operating Temperature: -40°C to 60°C (-40°F to 140°F) |
| Operating Temperature: 10°C to 35°C (50°F to 95°F) |